Care and Maintenance of Adjustable Safety Razors
25 November 2019MERKUR FUTUR
1. Remove top cap.
2. Press down the blade base and turn the handle counter clockwise while still pressing the blade table down
3. Take out the base with the spring. Pay attention to the direction of the spring, do not change it.
4. Clean and disinfect all the parts with SterimedEndo Ready disinfectant. Leave the parts in the solution for about 20 minutes to remove all soap, oil and lime residues.
5. Then take all parts and rinse with clean water and dry with a soft microfiber towel. Lightly oil the threads with thin machine oil or gun oil. Do not use any kinds of vegetable organic oils as they are acidic in structure.
6. Insert the spring in the same direction in the bottom part of the base.
7. Turn the handle clock wise while still pressing the blade base down to assembly the razor.
8. Clip the top back on and your razors is ready to use.
MERKUR PROGRESS
Now let's look at Merkur Progress.
1. First remove the top head plate by turning the adjustment knob counter clockwise.
2. Remove the lower adjusting part by pulling the button down. Do not attempt to remove the blade base. This part is permanently fixed at the factory.
3. Clean and disinfect all the parts with SterimedEndo Ready disinfectant. Leave the parts in the solution for about 20 minutes to remove all soap, oil and lime residues. Then take all parts out and rinse with clean water and dry with a soft microfiber towel.
4. For assembly, squeeze the metal ring on the adjusting piece, and push this part into the handle making sure it is secured in place.
5. Put back the head plate by making sure that the line mark on it corresponds with the triangular mark on the base plate.
6. Tighten the adjustment knob fully clockwise. When fully screwed the setting will be at the setting 1 or very near it. Then adjust the setting to your desired number. Your razor is ready to use.
PARKER VARIANT ADJUSTABLE
Finally, let's look at the Parker Variant Adjustable safety razor. This razor is very similar to Merkur Progress, and the whole process is almost the same.
1. First remove the top head plate by turning the adjustment knob counter clockwise.
2. Remove the lower adjusting part by pulling the button down. Do not attempt to remove the blade base. This part is permanently fixed at the factory.
3. Clean and disinfect all the parts with SterimedEndo Ready disinfectant. Leave the parts in the solution for about 20 minutes to remove all soap, oil and lime residues. Then take all parts and rinse with clean water and dry with a soft microfiber towel.
4. Insert the adjusting piece into the handle by pushing it and make sure it is secured in place.
5. As with Merkur Progress, you must squeeze the ring in the middle when inserting this piece.
6. Put back the head plate by making sure that the line mark on it corresponds with the line mark on the base plate.
7. Tighten the adjustment knob fully clockwise. Then adjust the setting to your desired number. Your razor is ready to use.
May your shaving pleasure ever last